9999 in stock
UPA-2P : Compact Narrow Coverage Loudspeaker
The UPA-2P loudspeaker provides high power output, low distortion, and consistent polar response in a compact, vented two-way enclosure. The loudspeaker features a 12-inch cone low-frequency driver and a 3-inch-diaphragm compression driver coupled with a 45-degree symmetrical high-frequency horn. The versatile UPA-2P has many sound reinforcement applications, as a main front-of-house loudspeaker in smaller venues (as a stand-alone set or in arrays), as a delay or fill loudspeaker in larger systems, and more.
The UPA-2P is distinguished by the extraordinarily smooth and predictable behavior of its proprietary horn. Uniformly predictable polar behavior takes much of the guesswork out of system design, and ensures arrays that exhibit minimal destructive interference.
Each driver is individually powered by a dedicated channel of the proprietary class AB/bridged amplifier with complementary MOSFET output stages. Total power is 550 watts. The incoming audio signal is processed through an electronic crossover and correction filters for flat phase and frequency response as well as for driver protection. Phase-corrected electronics ensure flat acoustical amplitude and phase response, resulting in exceptional impulse response and precise imaging.
Audio input modules accommodate a range of applications. The standard version offers looping XLR input and output connectors, while an enhanced looping version adds polarity switching (the looping output is not affected) and input attenuation (0 dB to -18 dB).
The durable trapezoidal enclosure is covered with a black textured hard-shell finish. A protective hex-stamped steel grille and charcoal grey foam cover are included. Standard rigging points are four ring and stud pan fittings (two on top and bottom) with a load rating of 420 lbs (190.51 kg) at a 5:1 safety factor. The optional 30-degree rigging frame, mounting yoke and pole mount adapters allow fast, flexible installation and easy aiming.
Specifications
Acoustical:
Operating Frequency Range1 60 Hz - 18 kHz
Frequency Response2 80 Hz - 17 kHz ±4 dB
Phase Response 600 Hz - 16 kHz ±35°
Maximum Peak SPL3 133 dB
Dynamic Range >110 dB
Coverage:
Horizontal 45°
Vertical 45°
Crossover:
Frequency 1000 Hz
Transducers:
Low Frequency One 12" cone driver
Nominal impedance: 2Ω
Voice coil size: 3"
Power-handling capability: 400 W (AES)5
High Frequency One 3" compression driver
Nominal impedance: 16Ω
Voice coil size: 3"
Diaphragm size: 3"
Exit size: 1.4" throat
Power-handling capability: 100 W (AES)5
Audio Input:
Type Differential, electronically balanced
Maximum Common Mode Range ±15 V DC, clamped to earth for voltage transient protection
Connectors Female XLR input with male XLR loop output or VEAM all-in-one
(integrates AC, audio and network)
Input Impedance 10 kΩ differential between pins 2 and 3
Wiring Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to
provide virtual ground lift at audio frequencies
Pin 2: Signal +
Pin 3: Signal - (optional polarity reversal switch)6
Case: Earth ground and chassis
DC Blocking Differential DC blocking up to maximum common mode voltage
CMRR >50 dB, typically 80 dB (50 Hz – 500 Hz)
RF Filter Common mode: 425 kHz; Differential mode: 142 kHz
TIM Filter <80 kHz, integral to signal processing
Nominal Input Sensitivity 0 dBV (1 V rms, 1.4 V pk) continuous average is typically the onset of
limiting for pink noise and music
Input Level Audio source must be capable of producing a minimum of +20 dBV
(10 V rms, 14 V pk) into 600 Ω to produce maximum peak SPL over
the operating bandwidth of the loudspeaker
Amplifier:
Type Two-channel complementary MOSFET output stages (class
AB/bridged)
Output Power7 550 W total
THD, IM, TIM <.02 %
Load Capacity 2 Ω low channel, 16 Ωhigh channel
Cooling Convection; 24 V DC output for optional external fan
AC Power:
Connector PowerCon or VEAM
Voltage Selection Automatic, continuous range from 90 V AC to 265 V AC
Safety Agency Rated Operating Range 100 V AC - 240 V AC; 50/60 Hz
Turn-on and Turn-off Points8 90 V AC on, no turn-off, only fuse-protect above 265 V AC
Current Draw: Idle Current 0.25 A rms (115 V AC); 0.13 A rms (230 V AC); 0.3 A rms (100 V AC)
Max Long-Term Continuous Current (>10 sec) 2.8 A rms (115 V AC); 1.4 A rms (230 V AC); 3.2 A rms (100 V AC)
Burst Current (<1 sec) 3.2 A rms (115 V AC); 1.6 A rms (230 V AC); 3.7 A rms (100 V AC)
Ultimate Short-Term Peak Current Draw 5.0 A pk (115 V AC); 2.5 A pk (230 V AC); 5.8 A pk (100 V AC)
Inrush Current <9 A pk (115 V AC and 230 V AC)
Notes:
Excel Presentations
Phone: 407-412-9001
[email protected]